FF102/50 Intumescent Cavity Barrier

Designed for installation within rainscreen / timber frame cavities. FF102/50 Intumescent Cavity Barrier are high expansion intumescent cavity barriers for location within 50mm wide ventilated voids.   Tenmat logo

download pdf
enquire now

Specification

  • Designed for installation within rainscreen / timber frame cavities
  • Accommodates a maximum void of 50mm
  • Provides a 44mm clear ventilated void
  • Simple installation process
  • Suitable for installation against timber substrates
  • Tested to the general principles of BS 476 Part 20: 1987
  • Suitable for both vertical and horizontal orientation
  • Provides between 30–60 mins fire resistance performance

Fire Performance

Product Dimensions Construction Type Assessed Performance
Vertical Horizontal
AIM FF102/50 6mm x 75mm x 1m Timber Frame 60 mins ** 30 mins **

** AIM FF102/50 has been tested and assessed to the general principles of BS 476 Part 20: 1987 by Chiltern International Fire. The above noted fire resistance performance is based on the barrier being installed against an OSB timber faced construction (Report Chilt/A10030).