Rockwool to polythene DPC Fire Closer
The Rockwool insulation used for the horizontal closer is precompressed to enable it to take up any minor irregularity in the wall void. This procedure also makes the insulation more flexible and easier to handle. The product benefits from zero ozone depletion potential and no CFCs or HCFCs are used in manufacture.
Fire Performance
The mineral wool is non-combustible in accordance with BS476 part 4 (1970). The DPC conforms to BS6515 (1984). The Closer conforms with the 1994 Building Regulations and the National House Building Council Requirements. AIM Horizontal Closers comply with Approved Document E 2003 to the Building Regulations 2000.
The AIM Horizontal Fire Closer will provide at least 2 hours resistance to the spread of fire past the separating floor, when installed immediately above a row of metal wall ties or when installed with fixing clips.
Acoustics
The AIM Horizontal Fire Closer has also been designed to provide resistance to the passage of flanking sound within the wall cavity adjacent to separating floors and complies with the requirements of Part E of the Building Regulations. AIM Horizontal Fire Closer also complies with the requirements of Robust Details.
Installation
The AIM Horizontal Fire Closer should be installed in the external cavity wall at the level of the separating floor. The closer is installed with the wide DPC overlap uppermost, as indicated in the illustrations with the DPC embedded into the inner blockwork in the mortar layer above the closer, so as to form a cavity tray.
If being used as a fire closer the product must be positioned immediately above a row of metal wall ties. If this is not possible the Horizontal Closer can be supplied with fixing clips. These are embedded into the mortar joint above floor level and the Horizontal Closer is impaled onto the clips.